The DS250E is an extreme duty Type 1+2 designed to protect the entrance of the electrical installation. The DS250E is a one-pole SPD and can be used in common mode or common and differential mode. DS250E AC surge protectors are designed to be connected in multi-pole configuration to protect single-phase, 3-phase and 3-phase+neutral AC networks. This SPD is DIN rail compatible,

Description

Electrical Characteristics

  • SPD type (following IEC tests): 1+2
  • Network: 230/400 V
  • Nominal line voltage Un: 400 V
  • Max. AC operating voltage Uc: 440 Vac
  • Max. load current(if series connection) IL: 100 A
  • Temporary Over Voltage (TOV) Characteristics – 5 sec (Without disconnection) UT: 580 Vac withstand
  • Temporary Over Voltage (TOV) Characteristics – 120 mn (Without disconnection or with safety disconnection) UT: 770 Vac disconnection
  • Residual Current Ipe: < 2 mA
  • Operating current Continuous current at Uc Ic: 2 mA
  • Follow current If: None
  • Nominal discharge current (15 x 8/20 µs impulses) In: 50 kA
  • Max. discharge current (max. withstand @ 8/20 µs by pole) Imax: 140 kA
  • Impulse current by pole (max. withstand 10/350µs by pole) Iimp: 25 kA
  • Specific energy by pole (max. withstand 10/350 µs) W/R: 156 kJ/ohm
  • Connection mode(s): L/N or L/PE
  • Protection mode(s): Common or Differential Mode
  • Protection level @ In (8/20µs)) Up: 2.5 kV
  • Admissible short-circuit current Isccr: 50 000 A
  • Internal short circuit protection: No
  • Internal Thermal protection: Yes

Mechanical Characteristics

  • Technology: MOV
  • Connection to Network: By screw terminals: 6-35mm² / by bus
  • Format: 1-pole modular box assembled
  • Mounting: Symmetrical rail 35 mm (EN 60715)
  • Housing material: Thermoplastic UL94 V-0
  • Operating temperature: -40/+85°C
  • Protection rating: IP20
  • Failsafe mode: Disconnection from AC network
  • Disconnection indicator: 3 mechanical indicators
  • Remote signaling of disconnection: Output on changeover contact
  • Dimensions: See diagram

Disconnectors

  • Thermal disconnector: Internal
  • Installation ground fault breaker: Type S or delayed
  • Fuses: Fuses Type gG – 315 A

Standards

  • Standards compliance: IEC 61643-11 / EN 61643-11 / Ul 1449
  • Certification: EAC